Peptide glossary

72 terms you will meet on a peptide lab report or research page, in plain words.

This glossary defines the terms used on research peptide certificates of analysis: what a peptide is, what HPLC purity and mass spec identity mean, how net peptide content differs from purity and from the label claim, what endotoxin screening is, how storage affects a result, and what the research terms on a product page mean.

Peptide basics
Amino acid
An amino acid is the building block of a peptide. Twenty standard amino acids, each with its own side chain, link end to end to form peptide chains.

Related: Peptide, Peptide bond

Peptide
A peptide is a short chain of amino acids joined by peptide bonds, usually from 2 to about 50 amino acids long. Longer chains are generally called proteins.

Related: Amino acid, Sequence, Solid-phase peptide synthesis (SPPS)

Peptide bond
A peptide bond is the chemical bond that links one amino acid to the next in a chain.

Related: Amino acid, Peptide

Sequence
A sequence is the exact order of amino acids in a peptide. Change one position and it is a different molecule with a different molecular weight.

Related: Molecular weight (Da), Deletion sequence

Molecular weight (Da)
Molecular weight is the mass of one molecule, measured in daltons (Da). Every sequence has a theoretical molecular weight that mass spectrometry can check against the sample.

Related: Mass spectrometry (MS), m/z (mass-to-charge ratio)

Solid-phase peptide synthesis (SPPS)
Solid-phase peptide synthesis is the standard way research peptides are made: amino acids are added one at a time to a chain anchored on a resin bead, then the finished chain is cut free and purified.

Related: Deletion sequence, Counter-ion

Lyophilized
Lyophilized means freeze-dried. The water in a peptide solution is frozen and then removed under vacuum, leaving a dry powder or cake. A lyophilized peptide is far more stable in storage than the same peptide in liquid, as long as it stays cold, dark and sealed.
On a real report: appearance "white lyophilized powder".

Related: Hygroscopic, Water content (Karl Fischer), Freeze-thaw cycle

Research use only (RUO)
Research use only is a label meaning a material is supplied for laboratory research and identification only. It is not for human or animal use and has not been evaluated by the FDA.

Related: Certificate of analysis (COA)

Pentadecapeptide
A pentadecapeptide is a peptide made of 15 amino acids. BPC-157 is one example: a linear chain of 15 residues with the sequence GEPPPGKPADDAGLV.
On a real report: BPC-157, 15 amino acids, 1419.5 g/mol.

Related: Peptide, Sequence, Tripeptide

Tripeptide
A tripeptide is a peptide made of three amino acids. GHK (glycyl-histidyl-lysine) is one example.

Related: Peptide, Peptide–metal complex, Pentadecapeptide

Peptide–metal complex
A peptide–metal complex is a peptide bound to a metal ion. GHK-Cu is the tripeptide GHK bound to a copper(II) ion. The complex has its own molecular formula, molecular weight and CAS number, different from those of the free peptide.
On a real report: GHK-Cu, C14H24CuN6O4, 403.9 g/mol.

Related: Tripeptide, Molecular formula, CAS number

Molecular formula
A molecular formula lists the atoms in one molecule and how many of each, such as C62H98N16O22. It should match the compound named on the label, including any metal or salt form.
On a real report: BPC-157, C62H98N16O22, matched on the certificate.

Related: Molecular weight (Da), CAS number, Identity

CAS number
A CAS number is a unique registry number the Chemical Abstracts Service assigns to one specific chemical substance. A free peptide and its salt or metal complex can carry different CAS numbers, so the number should match the exact form supplied.
On a real report: BPC-157, CAS 137525-51-0; GHK-Cu, CAS 89030-95-5.

Related: Molecular formula, Peptide–metal complex

On the lab report
Certificate of analysis (COA)
A certificate of analysis is the lab report for one specific batch of a peptide. It lists each test that was run, the method used, the specification the batch had to meet and the result, along with the lot number and test dates. A COA describes the lot it was written for and no other.
On a real report: lot SK10, received June 8 and reported June 9, 2026, with purity, identity, net content, endotoxin and appearance results.

Related: Lot number (batch number), Specification (spec), Chromatographic purity, Identity

Lot number (batch number)
A lot number is the code that ties a vial to its batch and its report. The number on the vial should match the number on the COA.
On a real report: Lot SK10.

Related: Lot vs batch, Certificate of analysis (COA)

Lot vs batch
A batch is the quantity made in one production run; a lot is a quantity identified by one number for testing and release. Many suppliers use the two words interchangeably.

Related: Lot number (batch number)

Lab reference (accession number)
A lab reference is the testing lab's own ID for the sample it received. It is useful when asking a lab or supplier to confirm a result.

Related: Certificate of analysis (COA)

Specification (spec)
A specification is the bar a result had to clear, such as "at or above 98.0%". A result only means something next to its specification.

Related: Acceptance criteria (pass/fail), Chromatographic purity

Acceptance criteria (pass/fail)
Acceptance criteria are the set of specifications a lot must meet, test by test, to pass. Each result on a COA is marked against its criterion.

Related: Specification (spec), Released / not released

Assay
An assay is a test that measures how much of a substance is present. On a peptide COA it usually refers to the quantitative test behind purity or net content.

Related: Chromatographic purity, Net peptide content

Label claim
A label claim is the amount printed on the vial, such as 10 mg.

Related: Net peptide content

Net peptide content
Net peptide content is the actual mass of peptide in a vial, not counting water, counter-ions such as acetate or TFA, and other non-peptide material. It is measured on its own, apart from purity, and it is not purity multiplied by the label weight. It is rarely identical to the label claim and can sit slightly above or below it.
On a real report: 11.08 mg measured against a 10 mg label claim (lot SK10); 10.53 mg against 10 mg (lot TSM10).

Related: Label claim, Counter-ion, Water content (Karl Fischer), Chromatographic purity

Read the full net peptide content guide

Counter-ion
A counter-ion is a small charged molecule that pairs with a peptide as a salt. It adds weight to the powder but is not peptide, which is one reason net peptide content is lower than the weight of the powder.

Related: TFA (trifluoroacetate), Acetate, Net peptide content

TFA (trifluoroacetate)
TFA is a counter-ion left over from peptide synthesis and purification, where trifluoroacetic acid is used to cut and wash the chain. A peptide supplied as a TFA salt carries it as part of its weight.

Related: Counter-ion, Acetate, Solid-phase peptide synthesis (SPPS)

Acetate
Acetate is a counter-ion often used in place of TFA after an exchange step. A peptide supplied as an acetate salt carries acetate as part of its weight.

Related: Counter-ion, TFA (trifluoroacetate)

Appearance
Appearance is a visual check of the vial contents, such as color and form.

Related: Lyophilized

Released / not released
Released means a lot met its release criteria and went on sale; not released means it did not. A lot can score well on one test and still not be released because of another.
On a real report: lot CP10, 99.85% purity, identity failed, not released.

Related: Acceptance criteria (pass/fail), Identity

ISO/IEC 17025 (accredited lab)
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. An accredited lab has been assessed by an independent accreditation body, such as A2LA or PJLA, for specific named methods. Accreditation covers those methods, not every test a lab offers.
On a real report: pH Solutions, ISO/IEC 17025:2017, A2LA R243 and PJLA Testing #84351.

Related: Certificate of analysis (COA), Lab reference (accession number)

Testing methods
HPLC (high-performance liquid chromatography)
HPLC is a method that separates a sample into its components and measures each one. It is the standard test for peptide purity.

Related: HPLC-UV, Chromatogram, Chromatographic purity

HPLC-UV
HPLC-UV is HPLC with an ultraviolet detector, which records each component as it absorbs UV light. It only sees material that absorbs at the chosen wavelength.
On a real report: Chromatographic purity, HPLC-UV, 99.82%.

Related: HPLC (high-performance liquid chromatography), Chromatographic purity

Chromatogram
A chromatogram is the graph HPLC produces: peaks plotted against time. One tall peak is the target peptide; small peaks are impurities.

Related: Retention time, Impurity, Chromatographic purity

Retention time
Retention time is how long a component takes to pass through the HPLC column. A given peptide comes out at a characteristic time for a given method.

Related: Chromatogram, Reference standard

Chromatographic purity
Chromatographic purity is the area of the main peak as a share of all detected peaks on an HPLC trace, reported as a percentage. It shows how clean a sample is. It does not show which compound the main peak is, and it does not measure how much peptide is in the vial.
On a real report: HPLC-UV purity 99.82%, spec at or above 98.0%.

Related: Identity, Net peptide content, Chromatogram

Impurity
An impurity is anything in the sample other than the target peptide, such as deletion sequences, oxidized forms or closely related chains left over from synthesis.

Related: Deletion sequence, Oxidation

Deletion sequence
A deletion sequence is a peptide chain missing one or more amino acids, usually from an incomplete step during synthesis. It is one of the most common impurities and shows up as a separate peak.

Related: Impurity, Solid-phase peptide synthesis (SPPS), Sequence

Mass spectrometry (MS)
Mass spectrometry is a method that measures molecular weight. Comparing observed weight with theoretical weight confirms a peptide's identity.

Related: LC-MS, m/z (mass-to-charge ratio), Identity

m/z (mass-to-charge ratio)
m/z is the mass-to-charge ratio a mass spectrometer actually measures. A peptide can carry more than one charge, so the instrument works back from m/z to the molecular weight.

Related: Mass spectrometry (MS), Molecular weight (Da)

LC-MS
LC-MS is liquid chromatography coupled to mass spectrometry. The sample is first separated, then each part is weighed, so the instrument can confirm that the main component has the molecular weight of the labelled peptide. It is the usual method behind an identity result on a COA.
On a real report: Identity, LC-MS, Confirmed.

Related: Mass spectrometry (MS), Identity, HPLC (high-performance liquid chromatography)

Identity
Identity is confirmation that the compound in the vial is the one on the label, usually by mass spectrometry or by matching a certified reference standard.

Related: LC-MS, Reference standard, Chromatographic purity

Reference standard
A reference standard is a certified sample of a known compound. A lab can confirm identity by showing that a test sample behaves the same way, for example the same HPLC retention time.

Related: Identity, Retention time

Limit of detection
The limit of detection is the smallest amount a test can reliably detect. A result reported as "below" a value means nothing was found above that limit.
On a real report: endotoxin below the 0.05 EU/mL sensitivity of the assay.

Related: EU/mL, Endotoxin

pH
pH measures how acidic or basic a sample is once dissolved, on a scale from 0 to 14, where 7 is neutral.
On a real report: pH 7.0.

Related: Appearance

Contaminant screens
Endotoxin
Endotoxin is a molecule from the outer wall of certain bacteria. It does not show up on HPLC, so labs screen for it with a separate test, usually the LAL test, and report the result in endotoxin units per milliliter (EU/mL).
On a real report: pass, below the 0.05 EU/mL sensitivity of the assay.

Related: LAL (limulus amebocyte lysate), EU/mL, USP <85>

LAL (limulus amebocyte lysate)
The LAL test is the standard lab test for endotoxin. It uses a reagent made from horseshoe crab blood cells that reacts to endotoxin, and the result is read against a set limit. The method is described in USP chapter 85.

Related: Endotoxin, EU/mL, USP <85>

EU/mL
EU/mL means endotoxin units per milliliter, the unit an endotoxin result is reported in.

Related: Endotoxin, Limit of detection

USP <85>
USP <85> is the United States Pharmacopeia chapter that describes the bacterial endotoxins test. A COA may cite it next to an endotoxin result.

Related: LAL (limulus amebocyte lysate), Endotoxin

Heavy metals (ICP-MS)
A heavy metals screen tests for trace metals such as lead, arsenic, cadmium and mercury, usually by inductively coupled plasma mass spectrometry.

Related: Residual solvents

Residual solvents
Residual solvents are traces of solvents left over from synthesis and purification, measured against set limits.

Related: Solid-phase peptide synthesis (SPPS), TFA (trifluoroacetate)

Water content (Karl Fischer)
Water content is how much water is in the powder, usually measured by Karl Fischer titration. Freeze-dried peptides still hold a small amount.

Related: Lyophilized, Hygroscopic, Net peptide content

Water activity (aw)
Water activity measures how available the water in a sample is, on a scale from 0 to 1. It is different from water content: water content is how much water is present, while water activity reflects how freely that water could support microbial growth or chemical change. Lower is drier.
On a real report: 0.0425 aw (GHK-Cu Pro lot NHS-GHK100-20260828-01).

Related: Water content (Karl Fischer), Hygroscopic, Microbial panel

Microbial panel
A microbial panel is a set of tests for bacteria, yeast and mold in a sample, such as E. coli, Salmonella, Aspergillus species, coliforms and total aerobic count. Each organism is reported as detected or not detected.
On a real report: 10 organisms and counts, all not detected.

Related: Sterility test, Mycotoxins, Endotoxin

Sterility test
A sterility test checks whether a sample contains any living microorganisms by placing it in growth media and watching for growth. It is a pass or fail result. It is separate from endotoxin testing, which detects bacterial debris rather than live organisms.
On a real report: Sterility, pass.

Related: Microbial panel, Endotoxin

Mycotoxins
Mycotoxins are toxic compounds made by certain molds, such as aflatoxins and ochratoxin A. A mycotoxin screen looks for these compounds, separately from the microbial panel, which looks for the molds themselves.
On a real report: Mycotoxins, pass.

Related: Microbial panel, Heavy metals (ICP-MS)

Storage and stability
Hygroscopic
Hygroscopic means tending to pull moisture from the air. Most freeze-dried peptides are, which is why vials stay sealed until use.

Related: Desiccant, Water content (Karl Fischer)

Freeze-thaw cycle
A freeze-thaw cycle is one round of freezing and thawing. Repeated cycles can break down a peptide, so samples are often split into portions before freezing.

Related: Degradation, Lyophilized

Degradation
Degradation is chemical breakdown over time, sped up by heat, light, moisture and oxygen. It lowers purity after the COA was issued.

Related: Oxidation, Freeze-thaw cycle, Chromatographic purity

Oxidation
Oxidation is a reaction with oxygen that changes some amino acids, especially methionine and tryptophan. It shows up as an extra peak on HPLC.

Related: Degradation, Impurity

Desiccant
A desiccant is a drying agent stored with vials to keep moisture down.

Related: Hygroscopic

Research terms
Preclinical research
Preclinical research is laboratory and animal work done before, or without, any study in people. A preclinical finding describes what happened in an experimental system. It does not show an effect in humans.

Related: In vitro, Ex vivo, In vivo

In vitro
In vitro means performed outside a living organism, in cells, tissue extracts or purified reagents in a dish or tube.

Related: Cell culture, Ex vivo, In vivo

Ex vivo
Ex vivo means performed on tissue taken from an organism and kept functioning outside it, such as a section of isolated blood vessel held in an organ bath.

Related: In vitro, In vivo

In vivo
In vivo means performed in a whole living organism. In published peptide research this usually means animal models such as rats or mice.

Related: In vitro, Preclinical research

Cell culture
Cell culture is the growth of cells in a controlled laboratory environment, outside the organism they came from. Most in vitro peptide studies use cultured cells.

Related: In vitro, Fibroblast, Endothelial cell

Fibroblast
A fibroblast is a connective tissue cell that produces collagen and other extracellular matrix proteins. Fibroblast cultures, from skin or tendon, are a common in vitro model.

Related: Cell culture, Gene expression

Endothelial cell
An endothelial cell is one of the cells that line the inside of blood vessels. Cultured endothelial cells are a standard model in vascular biology research.

Related: Cell culture, Nitric oxide (NO), eNOS (endothelial nitric oxide synthase)

Gene expression
Gene expression is the process by which a gene is used to make RNA and then protein. Studies measure it as mRNA levels, for example by RT-qPCR, or as protein levels, for example by Western blot.

Related: RT-qPCR, Western blot

RT-qPCR
RT-qPCR (reverse transcription quantitative PCR) converts RNA into DNA and then measures it as it is copied. It is the standard way to measure how much of a particular gene’s mRNA a sample contains.

Related: Gene expression, Western blot

Western blot
A Western blot separates proteins by size on a gel, transfers them to a membrane and detects one specific protein with antibodies. Studies use it to measure protein levels or modifications such as phosphorylation.

Related: Phosphorylation, Gene expression

Phosphorylation
Phosphorylation is the addition of a phosphate group to a protein, usually by an enzyme called a kinase. It switches many signaling proteins on or off, so studies often measure it as a readout of pathway activity.

Related: Western blot, eNOS (endothelial nitric oxide synthase)

Nitric oxide (NO)
Nitric oxide is a small signaling molecule made by cells. In blood vessels it is produced mainly by endothelial cells, through the enzyme eNOS. It is studied widely in vascular biology.

Related: eNOS (endothelial nitric oxide synthase), Endothelial cell

eNOS (endothelial nitric oxide synthase)
eNOS is the enzyme in endothelial cells that produces nitric oxide. Its activity is often tracked by measuring its phosphorylation.

Related: Nitric oxide (NO), Phosphorylation, Endothelial cell

PMID (PubMed ID)
A PMID is the unique number PubMed assigns to each article it indexes. Quoting the PMID lets anyone look up the exact study being cited.
On a real report: PMID 33051481, Hsieh et al., 2020.

Related: Preclinical research

No term matches that search. Try a shorter word.

See the terms on a real report

The fastest way to learn the words is to read a real certificate. Start with a guide, then open any lot in the library.

Common questions

What does net peptide content mean on a COA?

Net peptide content is the amount of peptide the lab actually measured in the vial, not counting water and counter-ions. The label claim is what the vial says. The two are rarely identical, and a COA should show the measured figure next to the label claim.

Is net peptide content the same as purity?

No. Purity, measured by HPLC, is the share of detected material that is the target peptide. Net peptide content is the mass of peptide in the vial. A powder can be 99% pure by HPLC and still carry part of its weight as water and counter-ions, so the two numbers answer different questions.

What is the difference between purity and identity?

Purity, usually measured by HPLC, is the share of detected material that is one main compound. Identity, usually confirmed by mass spectrometry, shows whether that compound is the one on the label. A sample can be very pure and still be the wrong compound.

What is endotoxin testing on a peptide COA?

Endotoxin is a molecule from the cell wall of certain bacteria that HPLC cannot detect. Labs screen for it with the LAL test, described in USP chapter 85, and report the result in endotoxin units per milliliter (EU/mL).

What does research use only mean?

Research use only (RUO) means a material is supplied for laboratory research and identification only. It is not for human or animal use and has not been evaluated by the FDA.

Research use only. All products are intended for research and identification purposes only. These products are not intended for human dosing, injection, or ingestion. The statements on this website have not been reviewed by the FDA. These research peptides are not intended to diagnose, treat, cure, or prevent any disease.